SIEMENS 6SE7014-0TP50-0TP60 SIMOVERT Control Inverter Unit

Siemens SIMOVERT MASTERDRIVES units with part numbers 6SE7014-0TP50 (Motion Control) and 6SE7014-0TP60 (Vector Control) are industrial AC frequency converters rated typically around 1.5 kW to 5 kW (depending on the exact sub-type/overload rating, such as 1.5 kW / 13 A output). Both product lines are phased out and discontinued by Siemens, with conditional repair services available through Siemens support or specialized third-party providers.

  • رقم الصنف :

    6SE7014-0TP50-0TP60
  • الطلب (الحد الأدنى للكمية) :

    1
  • قسط :

    EXW
  • منشأ المنتج :

    Germany
  • ميناء الشحن :

    Wuhan, Hubei, China
  • مهلة :

    3-5 days
  • وزن :

    3.4kg
  • 6SE7014-0TP50-0TP60 SIEMENS

    New in stock     

    Origin from Germany

    Payment Method: TT.Western Union

    Shipping Method: DHL\UPS\Fedex\EMS\Others 

    Specification

    Brand/Manufacturer Siemens
    Part Number 6SE7014-0TP50-0TP60
    MOQ 1PC
    Price The price is not real, please inquiry

    Trade Process

    Frequent Questions and Answers

    1. What do the 005 display state or parameter setting issues mean?

    • Cause: The 005 state often appears if parameter P060 is set to 5 (Drive Setting mode), or accidentally after a factory default reset.

    • Solution:

    • Check and adjust P060. Returning to normal operation typically requires setting P060 = 7.

    • Warning: If the drive has been factory-defaulted, you must run through hardware setting mode (P060 = 8) and configure parameter P070 with the correct hardware number before running, otherwise permanent damage can occur.

     

    2. How do you restore factory settings on this drive?

    • Procedure: Typically done via the parameter menu or OP1S/PMU operator panel using a sequence such as setting P053 = 6, P060 = 2, and P970 = 0 (refer to the official compendium for your exact software version).

     

    3. What should I check if the drive trips, fails, or burns out?

    • Common Causes:

    • Short circuits / Debris: Conductive metal dust or particles falling into the top/interior of IP20 chassis units.

    • Phase loss: Missing input supply phases or unstable line voltage.

    • Capacitor and DC link hazards: Even after disconnecting the main AC voltage supply, internal DC-link capacitors stay energized for a dangerous period. Always wait and verify zero voltage before touching terminals.

    Hot Selling

    6GK1503-3CB00    6ES7416-3XR05-0AB0 6ES7521-1BL00-0AB0
    6EP1334-2BA20    6ES7972-0BA12-0XA0 6ES7522-1BL01-0AB0
    6EP1333-2AA00 6ES7138-4FR00-0AA0  6ES7531-7KF00-0AB0
    6EP4135-0GB00-0AY0 6ES7136-6BA00-0CA0  6GK5216-0BA00-2AB2
    6ES7153-1AA03-0XB0    6ES7158-0AD01-0XA0 6GK5216-4GS00-2AC2
    6ES7321-1BL00-0AA0    6ES7193-4CC20-1AA0 6ES7151-3BA23-0AB0
    6ES7331-7NF00-0AB0    6ES7193-4CB20-0AA0 6ES7231-4HD32-0XB0
ترك رسالة
إذا كنت مهتمًا بمنتجاتنا وترغب في معرفة المزيد من التفاصيل، فيرجى ترك رسالة هنا، وسنرد عليك في أقرب وقت ممكن.
ترك رسالة
إذا كنت مهتمًا بمنتجاتنا وترغب في معرفة المزيد من التفاصيل، فيرجى ترك رسالة هنا، وسنرد عليك في أقرب وقت ممكن.