Important: The 50 A type current rating is the performance capacity of the solid-state relay. The actual permitted rated operational current depends on the connection method, heatsink, and cooling conditions. A suitable heatsink is required to achieve the full 50 A rating. The M4 screw terminal version is limited to approximately 50 A and 10 mm² conductor cross-section; for higher currents, the ring cable lug version (3RF2150-2AA04) is recommended.
What's Included
Note: Heatsink, function modules, and terminal covers are sold separately.
Why Buy From Us?
-
In Stock – Ready to ship immediately
-
Genuine Siemens Product – Factory original SIRIUS component
-
Warranty Included – Purchase with confidence
-
Technical Support – Application and heatsink sizing assistance available
Frequently Asked Questions (FAQ)
Q1: What is the Siemens 3RF2150-1AA04?
It is a single-phase SIRIUS 3RF2 solid-state contactor with a 50 A type current rating, 48–460 V AC operating voltage, and 15–24 V DC control signal. It uses zero-point switching and screw terminals for wear-free, noiseless load switching.
Q2: Does this device require a heatsink?
Yes. The 50 A rating is the type current (performance capacity). The actual permitted operational current depends on the heatsink and cooling conditions. A suitable heatsink must be used to achieve the full rating. Without adequate cooling, the permissible current is significantly lower.
Q3: What is zero-point switching?
Zero-point switching means the device turns on when the AC voltage crosses zero. This minimizes inrush current and electrical noise, extending the life of resistive loads such as heaters.
Q4: What is the control voltage for this variant?
The 1AA04 variant uses a 15–24 V DC control signal. For a 24 V DC/AC control variant, see the 1AA14 model.
Q5: What is the minimum load current?
The minimum load current is 500 mA. Loads drawing less than this may not switch reliably.
Q6: Can I use this for inductive loads?
Yes. The device is designed for switching resistive and inductive loads, such as valves and solenoids. The zero-point switching helps reduce stress on inductive loads.
Q7: What is the power loss at rated current?
The power loss is 66 W at the rated current in hot operating condition. This heat must be dissipated by the heatsink.
Q8: What are the dimensions and weight?
Dimensions are 22.5 × 85 × 48 mm (W × H × D). Net weight is approximately 0.068–0.072 kg.
Q9: What is the country of origin?
Germany (DE).
Q10: What should I verify before ordering?
Always verify the exact part number (3RF2150-1AA04 for 15–24 V DC control), confirm your load current and voltage are within the 50 A / 48–460 V AC range, ensure you have a suitable heatsink for your required current, and check whether you need the ring cable lug version (3RF2150-2AA04) for higher current connections.